Inspiration

Over 2.2 billion people globally live with vision impairment (WHO). Their needs span the whole day, indoors and outdoors:

  • A person with cataracts is blinded by specular glare off wet pavement and kitchen counters.
  • A person with macular degeneration cannot read a prescription bottle, an appliance panel, or a transit departure board.
  • A person with advanced glaucoma facing a stairwell or curb encounters the deadliest classical computer vision failure there is.

To a standard 2D edge detector (Canny, Sobel, Laplacian), a 15 cm physical step-down is mathematically indistinguishable from a flat painted bicycle-lane stripe or a dark tree shadow- all three are high-gradient luminance contours. Alert on every edge and the user experiences alarm fatigue; suppress alerts and a stair becomes a fall. And generic algorithms apply uniform contrast enhancement to every user, ignoring the patient's individual ophthalmic profile: an AMD patient with a central scotoma needs peripheral contrast; a glaucoma patient with tunnel vision needs central clarity.

We built GozVision to answer one question per frame, correctly: what does this specific patient's remaining vision need from this frame, and is this edge a real hazard or a coplanar pattern? An autonomous, clinical-grade Agentic Vision Copilot built natively on OpenCV 5.0, measured on AWS Graviton, with an air-gapped local WebGPU option for clinical privacy.

What it does

GozVision unites real-time edge computer vision with clinical EHR intelligence across two connected surfaces:

Goz Patient Copilot (B2C PWA / Mobile):

  • Full Aid Suite (synchronous display): CIE-LAB adaptive CLAHE applied to luminance only (preserving chromaticity); Telea fast-marching inpainting (cv2.inpaint) to suppress specular glare from wet pavement and headlights for cataract patients; morphological reading-zone isolation that finds and highlights text blocks - medication labels, appliance panels, signage - for OCR and text-to-speech readout.
  • DAVE - Diagnosis-Adaptive Vision Enhancement: ingests the patient's FHIR ICD-10 codes (AMD H35.31, Glaucoma H40.11, Cataract H26.9, RP H35.52) and Humphrey Visual Field mean deviation to concentrate contrast gain in functioning retina instead of wasting it on a scotoma.
  • Spatial-Depth Hazard Discriminator (the flagship): monocular depth disparity via cv2.dnn.readNetFromONNX (MiDaS-small), StereoSGBM triangulation when a stereo baseline exists, a RANSAC ground-homography parallax veto for coplanar surfaces, and the core innovation: the vertical depth-disparity gradient ((\partial D / \partial y)) test across the walking corridor, gated by a 5-frame TemporalHazardCoherenceTracker. Output is a decision -vertical_drop (with estimated cm) vs coplanar_clear - for curbs, staircases, transit gaps, and indoor level changes alike, with real shadows suppressed as coplanar.
  • Spatial Directional Acoustic Cues & Voice: translates the 3D hazard vector into panned directional audio and spoken warnings ("Caution: step down to your left") for open-ear smart-audio frames.
  • Agentic Closed Loop: a vertical drop > 10 cm rewrites the agent's plan from passive monitoring to collision avoidance; post-hazard IMU stumble telemetry triggers an autonomous encrypted SOS dispatch to caregiver and clinic with GPS coordinates and a 10-second cancel window; prescription-label OCR is cross-checked against the patient's active EHR medications and halts administration on conflict, escalating to a clinician. Verified live over MCP: a logged end-to-end session on our AWS endpoint shows a real stairs frame driving plan escalation → SOS dispatch → medication HALT (docs/AGENTIC_MCP.md §3, judge-runnable with --local).

Goz Clinic Suite (B2B Practice Management Web Hub):

  • Ambient Clinical Scribe: synthesizes doctor-patient dialogue into structured FHIR R4 and SOAP notes, with a runtime toggle between Cloud AI (HIPAA BAA zero-retention) and Air-Gapped Local WebGPU inference - 100% on-device, zero network packets.
  • DAVE Clinical Configuration: the practitioner's diagnosis and visual-field data dynamically configure the patient's mobile vision filters - the clinical profile literally becomes the computer-vision configuration.

How we built it

OpenCV 5 Vision Pipeline (backend/gozvision_vision/cv_pipeline.py):

  • Stage 1 (Optical Pre-processing): BGR → LAB color space; CLAHE on the L channel only with condition-adaptive clip limits; glare masks attenuated via morphological dilation and Telea inpainting; lateral hazard clusters isolated independently via an active drop mask (active_drop_mask) so curbs entirely in the left or right third of the corridor still produce precise lateral centroids for directional panning.
  • Stage 2 (DNN Depth Disparity Engine): ONNX depth models via cv2.dnn.readNetFromONNX with DNN_BACKEND_OPENCV; StereoSGBM when stereo hardware exists.
  • Stage 3 (Vertical Drop vs. Shadow Classifier): the (\partial D / \partial y) disparity-gradient test across the walking corridor, plus a RANSAC ground-homography veto and optical-flow scale calibration for monocular drop-height estimation.
  • Temporal Hazard Coherence: a 5-frame rolling window enforces geometric consistency - geometrically stable steps hold coherence while fluctuating ground shadows collapse and are suppressed as coplanar_clear.

Cloud-Optimized OpenCV (COOL) on AWS Graviton (backend/gozvision_vision/cool_pipeline.py):

  • Production runs the linux/arm64 container on Graviton-backed Amazon ECS Fargate (CpuArchitecture: ARM64 in infra/gozvision-stack.yaml), with Universal Intrinsics SIMD vectorization; supports CV_8U, CV_32F, and CV_16BF datatypes.
  • Benchmarked head-to-head on real AWS Spot instances - Graviton2 (t4g.small) vs Intel x86 (c7i-flex.large) - identical OpenCV 5.0.0 build and DNN model on both sides (scripts/run_graviton_benchmark.sh).

Agentic Vision & Spatial Audio (backend/gozvision_agent/agentic_vision.py):

  • Multi-step perception-to-action workflows exposed as MCP tools over streamable HTTP: vision output rewrites the agent's goal state and drives send_sos_alert, log_adherence_event, and clinical SOAP-note drafting. Directional audio cues via the Web Audio API.

Cloud Infrastructure:

  • Amazon ECS Fargate (gozvision-cluster), AWS CloudFront TLS edge termination (d7icpdzxenshi.cloudfront.net), AWS Amplify hosting (main.d1lr4zsb46he1m.amplifyapp.com), Supabase PostgreSQL 16 with multi-tenant Row-Level Security.

Challenges we ran into

  • Distinguishing 2D texture from 3D geometry with commodity monocular hardware was the core research problem. Single-frame classification of curbs vs shadows is genuinely hard - our honest single-frame number is a 0.66 F1 smoke test. The homography veto and 5-frame temporal coherence window were born from those failure cases: with temporal approach context, the same classifier reaches 71.4% recall / 100% precision / 0.0 false alarms per minute on labelled approach sequences.
  • Lateral curb boundary dropouts: curbs entirely within the left or right third of the corridor initially produced zeroed bounding boxes. The active drop mask now isolates lateral hazard clusters independently, with regression-test coverage.
  • Evaluating vision quality for scotoma patients: full-frame SSIM penalizes adaptive enhancement because it averages pixel changes over blind retinal regions. We formulated Sighted-Region SSIM and a Contrast Improvement Index weighted to functioning retinal areas derived from visual-field tests - and it changes conclusions (documented in the eval report §8).
  • Epistemic honesty in benchmarking: our first benchmark draft attributed numbers to hardware they never ran on. We rewrote the benchmark to refuse cross-architecture claims that aren't measured - every number below now carries its environment label and telemetry, and we think the submission is stronger for it.

Accomplishments that we're proud of

  • Measured AWS Graviton economics on real Spot instances (identical benchmark, both sides -backend/benchmark_results_graviton_t4g_small.json, benchmark_results_x86_c7i-flex_large.json):
    • Per-dollar result: Graviton2 processes the identical workload 2.5–4.0x cheaper per 1M frames (contrast \$0.043 vs \$0.169; glare \$0.094 vs \$0.368; reading ROI \$0.0078 vs \$0.0285; spatial-depth DNN \$1.17 vs \$2.87) — the decisive economics for always-on assistive computing.
    • Per-core trade-off, stated honestly: the newer-generation Intel instance is 1.29–2.08x faster in raw throughput; Graviton wins on cost.
  • Dev-workstation measurements (640x480, MiDaS-small DNN active): spatial depth 12.4 FPS, contrast 414 FPS, glare suppression 71 FPS, reading-zone isolation 919 FPS (backend/benchmark_results.json).
  • A reproducible evaluation harness on real imagery: 69 real street/corridor frames (zero synthetic placeholders, Wikimedia-licensed, per-case SHA-256 recorded). We publish our own failure list - all 20 residual failures named by filename in docs/EVALUATION_REPORT.md §5.
  • DAVE, measured on sighted regions: condition-specific contrast amplification across pathology cohorts is statistically significant in our in-silico trial ((N=100), one-way ANOVA (F(3,96) = 7.51, p < 0.001)) - explicitly a simulation, not a clinical trial.
  • A true closed agentic loop, verified live - not narrated: vision results change what the system does next, and we can prove it end to end. scripts/run_agentic_mcp_session.py runs a logged MCP session against our live AWS endpoint: a real stairs photo (SHA-256 recorded in the log) goes through the OpenCV 5 spatial_depth tool, detects an elevation_barrier (~21 cm drop), the client decision rule escalates the plan, the agentic_vision_hazard_loop executes a 4-step perception→reasoning→actuator→tool_call trace that dispatches a real SOS alert (firestore_written: true), and the medication guardrail HALTS a contraindicated drop and escalates to clinician review - all with human_approval_required: true at both escalation points. The raw session log with per-step latencies is preserved at backend/evaluation/results/agentic_mcp_session_trace.json (zero errors), the same command runs with --local for offline judging, and the telemetry call inside the same session attests is_aws_graviton_arm: true on the production task. Full trace: docs/AGENTIC_MCP.md §3.
  • Privacy sovereignty: instant runtime toggle between cloud HIPAA BAA processing and 100% on-device WebGPU inference - zero biometric or clinical frames leave the room when required.

What we learned

  • The (\partial D / \partial y) disparity-gradient test is a cheap, effective coplanarity discriminator - but only with temporal context. Single-frame numbers collapse; temporal approach kinematics are what separate a curb from its shadow.
  • Perception must drive actuation. Patients with severe vision loss cannot interpret visual bounding boxes; the loop only closes when spatial perception becomes directional audio, haptics, and emergency actuation.
  • Full-frame metrics are the wrong metric for scotoma patients - sighted-region weighting flips conclusions, and clinical context (ICD-10 + HVF) should configure the CV pipeline before frame one.
  • Honest evaluation survives judging better than a leaderboard. Every number in this submission names the hardware it ran on.

What's next for GozVision - OpenCV 5 Assistive Vision Copilot for Low Vision

  • Curated curb/stairs benchmark with surveyed cm ground truth and on-glasses stereo-rig validation of SGBM metric depth.
  • Multi-center low-vision clinic partnerships and an IRB protocol (drafted in repo docs) to measure real-world reduction in assistive-device abandonment and fall incidence.
  • Direct micro-firmware AR waveguide integration: compiling the CLAHE and drop-disparity pipelines to ultra-lightweight smart-glass microcontrollers.
  • Graviton CI benchmark job so the economics table stays measured, continuously.

Built With

Share this project:

Updates