DAMO

Retrofit the data center you already have, with evidence for every change.

DAMO reads the records an operating hall runs on, finds where they disagree, and tests every integration change before anyone touches the floor. Nemotron does the reading. Deterministic checks decide whether it was right.

NMC² · NVIDIA Nemotron · 8090 · MLH Best Use of Tiger Data · MLH Best Use of Vultr

Preflight: ATS-1 fails and takes out both pumps, the chilled-water loop and 18 racks


For each track

Track Where to look
NMC² The retrofit walkthrough (CDU placement, BMS mapping, witnessed wet test) and the Console incident. Both pivot on records that disagree with the field.
NVIDIA Nemotron Five live uses, each paired with a check the model can't influence. See Where Nemotron runs below.
8090 Modernize takes a real legacy Nagios–Redfish check to Prometheus rules, proven against the original plugin with held-out cases, a mutant and a decoy.
Tiger Data 115,584 meter readings in a hypertable with an hourly continuous aggregate. They set Preflight's load profile and independently confirm the ATS-1 finding.
Vultr Production deployment with the verification toolchain built into the image, so the harness runs real checks instead of scripted results.

Inspiration

Data-center electricity use is projected to roughly double from 485 TWh in 2025 to 950 TWh in 2030, with AI-focused data centers tripling theirs (IEA). A liquid-cooling retrofit costs around $2 million per MW against upwards of $11 million per MW for new liquid-cooled capacity (STL Partners), so operators are upgrading halls they already run. A recent example: ByteBridge retrofitted a live Oakland colocation site with 1 MW, 32 racks and 3 CDUs in four months, including leak-detection integration with the facility's BMS, testing and commissioning (ByteBridge).

The engineers doing that work don't lack tools. They lack one version of the truth. The floor plan, the cooling schematic, the BMS point list, the vendor manual and the maintenance log each describe the building a little differently, and the differences are where outages come from.

Two examples, recreated in our synthetic sample hall, drove the project:

  • A backup that isn't independent. The one-line diagram shows Pump A and Pump B on separate power paths. A 2023 work order and a 2024 maintenance log show both pump panels running through the same transfer switch, ATS-1. On paper the cooling is 2N. In the field it's N.
  • An alarm that goes to the wrong rack. A revised drawing moves leak sensor LD-2 to rack R3-01. The BMS mapping still says R3-02. The alarm fires, and the technician runs to the wrong rack with water on the floor.

Neither one shows up on a dashboard. Both show up when you read every record side by side, and that's work a model can speed up, as long as something other than the model checks the answer.

What it does

DAMO takes a retrofit from scattered records to a tested handover, then carries that record into operations.

Retrofit setup

Retrofit setup: cooling and power map with the LD-2 conflict and its sources

Six steps. Connect the project's documents, and DAMO maps the site: 21 components and 21 links, each marked confirmed, inferred, conflicting or missing, with the source line for every one. It recommends a CDU location against space, floor loading, pipe route, power and service clearance. The engineer picks the CDU, approves the install plan, and reviews the BMS mapping. Commissioning runs offline tests and a witnessed wet test. The wet test catches LD-2 naming the wrong rack, and the fix is a one-line config diff that cites the drawing it came from. A later firmware change renames every leak point; the regression suite catches it before handover. The retrofit engine (mapping, behaviour tests, oracle, monitor) is deterministic Python; the walkthrough replays a recorded run of it, and its agent narration is scripted.

Modernize

Modernize: Nemotron 3.5 Super recovering the legacy check through tool calls

Legacy monitoring is the other half of an old building, and migrations break it: Equinix's Smart View FAQ notes that after a BMS upgrade renamed assets, customers' custom alerts stopped working and had to be recreated (Equinix). DAMO takes a real check, the Texas Tech HPCC Nagios–Redfish plugin, to Prometheus rules. A Nemotron 3.5 Super agent reads the plugin and its Nagios objects through tool calls (20 in our recorded run), records each behaviour with its source line, and raises six questions the code can't answer, such as "who should actually be paged?" when the inherited recipient is nagios@localhost. The operator's answers become test expectations. The first candidate passes 1 of 6 cases; Nemotron repairs it from the visible failures only, while held-out cases stay sealed.

Preflight

Preflight agent answering through a cited simulate call

A what-if simulator for equipment work. Pick "ATS-1 fails" and the cascade runs across the graph: both switchgear feeds, both pumps, the chilled-water loop, 18 racks, 400 kW. It finds minimal cut sets, checks whether each redundant group is really independent, and ranks maintenance windows and plans. Ask "Are Pump A and Pump B independent?" and the agent answers through simulate and find_cut_sets calls, citing every number.

Console

Console: GPU-07 known-answer test mismatch while every health check is green

The night shift on the retrofitted hall. GPU-07 passes every health check (61 °C, 94% utilization, online) and still returns the wrong checksum on a known-answer test. The console ties the mismatch to the rack, its power and cooling feeds and recent work, then walks the operator through acknowledge, investigate, dispatch, verify recovery and hand off. Paging and work orders never wait on the model.

How we built it

Where Nemotron runs

Nemotron proposes. Something it can't influence decides.

Nemotron does Checked by
Discovery (Preflight, "Read with Nemotron"): proposes "X is fed from Y" from work orders and logs A quote validator. The quote must appear in the record word for word, read as a feed in that direction, and name two real inventory nodes.
Preflight agent (Nemotron 3.5 Super): answers questions through eight engine tools A citation validator. Any node or number not present in the tool results the answer cites is rejected.
Modernize recover and repair (Nemotron 3.5 Super): reads the legacy plugin and its Nagios objects and calls it against a Redfish mock (20 tool calls in our recorded run), then repairs the failing rules A harness that runs the original plugin, promtool and amtool. Held-out cases, a wrong-recipient mutant and an alert-everything decoy make sure the suite can fail.
Console investigation (Nemotron Nano): queries telemetry, the asset map, the logbook and the runbook, and returns cited hypotheses Kept out of the alert path. Rules, paging and work orders run with the model switched off.

Every live response is cached and labelled live, cached or scripted on screen. The Preflight agent's tools: simulate, find cut sets, evaluate plan, search plans, search docs, get node, get neighbors, and propose dependency.

Engine

(backend/engine/, pure Python, no model). Requirement groups (all, any, k_of_n, capacity) over a power and cooling graph. Support is computed as a least fixpoint, so dependency cycles are safe. Overloaded suppliers shed the lowest-criticality load first, and every failed node gets a causal trace. Minimal cut sets come from MOCUS expansion up to order 3, cross-checked against brute-force enumeration in the tests.

Tiger Data

Meter readings live in a TimescaleDB hypertable with an hourly continuous aggregate. The load profile Preflight plans against is the worst hourly average at each hour of the week over four weeks. Reconciliation correlates each meter's unexplained load with candidate consumers to catch equipment wired to a different supplier than documented.

That is how the meters back up the records. Next to the work order and the maintenance log, the ATS-1 finding cites: "ATS-1 carries 16.7 kW more than its documented loads and ATS-2 is short by about as much; both gaps track MCC-B's meter (r = 0.96 and −0.97 over 14 days)." The paperwork and the physics agree, and the one-line diagram is the outlier.

Tiger meter evidence cited beside the work order and maintenance log

Vultr

DAMO runs on a Vultr server with Docker Compose: an API container and a web container behind the server's Caddy, which terminates HTTPS. The API image downloads promtool 3.2.1, amtool 0.28.1 and jq 1.7.1 from their release pages and verifies each against its published SHA-256 before installing it. That matters for the demo: on a laptop without those tools the Verify harness falls back to scripted results and says so, while the Vultr image has everything it needs to run the real checks. Secrets live in an env file on the server, never in the repository, and SQLite state, the meter snapshot and recorded model replies sit on named volumes so they survive redeploys.

Stack

FastAPI backend, React + Vite + Tailwind frontend, NVIDIA Nemotron through build.nvidia.com's OpenAI-compatible API, with every live response cached so the demo replays offline and labels itself when it does. 168 backend tests, a 24-question agent eval, and a Playwright rehearsal that clicks through the demo and checks every number.

Challenges we ran into

  • Keeping the model out of the alert path. Rules, paging and work orders had to work with Nemotron switched off. The console has an online/offline toggle, and the alarm still fires and pages with it off.
  • Making the tests able to fail. A harness that passes everything proves nothing, so the suite must reject a wrong-recipient mutant and an alert-everything decoy before its passes count.
  • Model IDs move. A Nemotron model we built against was retired during the weekend and started returning HTTP 410. Model IDs are now configuration, and the UI shows which model and mode (live, cached, scripted) produced each answer.
  • Venue Wi-Fi blocked Tiger's port. Every meter sync now writes a local snapshot, and the app starts from it when Tiger is unreachable.

Accomplishments we're proud of

  • The ATS-1 finding falls out of the records automatically: discovery reads the work order, an engineer confirms it, and every critical service drops from 2N to N on screen.
  • Discovery holds 1.0 precision with 0.867–0.983 recall across 10 seeded sets of noisy records. Most misses are digit-swap typos that spell another real tag, which is the right way to fail.

What we learned

The useful job for an LLM in a data center is reading documents that disagree and producing proposals specific enough to check. Deterministic validation does the deciding.

What's next

  • Run against a real site's exported point list and drawings instead of the synthetic hall.
  • Call the retrofit backend live from the UI (today the setup screens replay a recorded run of it).
  • Extend the harness from Nagios to BMS vendor alarm logic, so a firmware update is tested the same way a rule change is.

Honest scope

The facility and its records are synthetic, and the retrofit walkthrough replays a recorded engine run. Power and cooling are modelled as kW budgets, and passing the harness is evidence on the stated scenarios, not a replacement for physical commissioning.

Built with

python fastapi typescript react vite tailwindcss nvidia-nemotron build.nvidia.com timescaledb tiger-data postgresql prometheus alertmanager nagios redfish playwright docker caddy vultr